Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 . 5 mm, the smallest class in the industry S82S-7305 DC 5V0.6A.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
S82S-7305 DC 5V0.6A
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Terminal: Screw terminal (-B).
Actuator: Panel mount cross roller plunger.
High-capacity Switch Capable of,
Handling 20 A Loads with Large S82S-7305 DC 5V0.6A.
Inrush Currents.
Same shape as OMRON Z Basic Switches except in pin,
plunger position, yet endures inrush currents as large as 75 A . 2 heat resistant devices.
Heat resistant device used as starting water tank water reducing alarm device.
Second control cabinet for pressurized water supply device is also supported.
Water reducing alarming device of heat resisting type starting water tank installed in control cabinet S82S-7305 DC 5V0.6A. Specifications: I/O;
PNP (input: - common, output: + common);
Input: 8 points/Output: 8 points .
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Lock method: Solenoid lock.
Conduit size: G1/2.
Voltage for solenoid: 24 VDC.
With LED indicator 2NC+ 1NC (Slow-action).
Release Protective Cover Locks Using.
Controller Signals or Pushbutton.
Switches after the Cutting Tool Stops.
Moving Due to Inertia.
A mechanical lock is applied automatically when the Operation.
Key is inserted. A high level of safety is achieved using a,
mechanism where the lock is only released when voltage is,
applied to the solenoid.
Conforms to EN (TÜV) standards corresponding to the CE marking.
Certified by UL, CSA and CCC standards.
The Switch contact is opened by a direct opening mechanism,
(NC contacts only) when the protective cover is opened.
Direct opening mechanism that is EN-certified is indicated by,
on the Switch.
Auxiliary release key ensures easy maintenance and unlocks the,
door in the case of a power failure.
Tough aluminum die-cast boddy incorporating a switch box with,
degree of protection satisfying IP67, UL, and CSA TYPE6P, 13 S82S-7305 DC 5V0.6A.
Equipped with a horizontal and vertical conduit opening.
Models incorporating easy-to-see indicators for monitoring and,
those using an adjustable Operation Key fforr a swinging door are available S82S-7305 DC 5V0.6A.
The mounting direction of the head can be changed,
to allow the Operation Key to be inserted from four directions.
S82S-7305 DC 5V0.6A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=S82S-7305 DC 5V0.6A&select=5