Size: M8(Stainless steel)(See note 2.); Single; Unshielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. No. of notches: 2 notches.
Output: SPDT.
Reset method: Automatic .
Lighting method: Non-lighted S8EX-P10005.
Separate Construction with Cylindrical.
16-dia
S8EX-P10005 Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads.
Oil-resistant IP65 models,
Conforms to EN60947-5-1. Models: OVGR (64).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched S8EX-P10005.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system S8EX-P10005.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring. Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance.
By improving the reliability of internal reelays (tiny load 1mA DC5VV), the PLC input becomes possible S8EX-P10005.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 wwayys S8EX-P10005.
Type: GN type, automatic water supply and drainage.
Package product name: 61F-GN base * 1, 61F-11_ unit * 1.
Purpose: long distance use (2km).
S8EX-P10005 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=S8EX-P10005&select=5