Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models . )
Sealing characteristics that meet IEC IP67 degree of protection SDV-FM4 DC100/110.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
SDV-FM4 DC100/110
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables SDV-FM4 DC100/110.
Multiple mounting possible with Switches with Plungers .
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Model : CV1000-DM641.
Available CV1000/2000/CVM1-CPU21-V2.
64K words.Type: Long-distance (for 2 km) SDV-FM4 DC100/110.
I models.
Compact, Space-saving Plug-in Type Ideal,
for Pump Panels or Building into Equipment .
Large switching capacity: 5 A at 220 VAC (resistive load).
Easy to handle with DIN rail mounting.
Replace for maintenance without rewiring the socket. Size: 48 x 24mm.
Control output 1: linear current output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: PUSH-IN fastening terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves thhe maintenance perfformance SDV-FM4 DC100/110.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set SDV-FM4 DC100/110.
It can be easily set by CS-Thermo (sold separately).
SDV-FM4 DC100/110 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SDV-FM4 DC100/110&select=5