The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply SE-KQ2EN.
Event input points: -.
Transfer output: output (using control output)
SE-KQ2EN
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement SE-KQ2EN.
E5CN-U (insert type) add analog input and current output type .
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Function name: 3 phase 200V.
Power: 0.75KW SE-KQ2EN.
Maximum output voltage: three phase 200 ~ 240VAC (corresponding input voltage) .
Rated voltage, frequency: three-phase power supply 200 ~ 50/60Hz, 240V.
Cooling way: natural wind cooling.
Weight: 1.1kg.
Simple but not simple, casual and not casual.
Homogenization of today, the quality of the subtle show.
Standard configuration has RS485 interface, Modbus bus communication function.
3Hz provides more than 150% torque output.
2-15kHz carrier frequency, can achieve mute driver.
Equipped with simple energy saving function.
Compact size and uniform, and can be installed close to the side by side.
Signal output function for controlling external brake action.
Software setting operation mode, no need to connect the control line can be used for speed control. Power ratings: 480 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 48 V.
Output current: 10 A.
Boost Current: 12 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 1220% SE-KQ2EN.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 4800-WW models) SE-KQ2EN.
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1.
SE-KQ2EN Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SE-KQ2EN&select=5