Actuator: Plunger.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement SGE-125-0-1040 05000C-05000C.
Standardized gold-clad contacts provide high contact reliability
SGE-125-0-1040 05000C-05000C
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver) SGE-125-0-1040 05000C-05000C.
Control output 2:--.
Auxiliary output: 3 points (common universal) .
Power supply voltage: AC100 ~ 240V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: -.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility SGE-125-0-1040 05000C-05000C.
Selection, operation and setting.
Functional performance of input and output points .
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a variety of applications.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermo (sold separately).
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication. Control supply voltage: 110 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal.
Preecisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out SGE-125-0-1040 05000C-05000C.
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with boothh single-phase and three-phase heaters SGE-125-0-1040 05000C-05000C.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage.
SGE-125-0-1040 05000C-05000C Operation manual / Instructions / Catalog download link: