Improved update. Reduce standby power consumption, and then achieve lightweight.
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance .
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible
SGE-225-0-0260L 05000C-05000C
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways SGE-225-0-0260L 05000C-05000C.
Type: G2N type, both full water alarm function of automatic water supply and drainage .
Package product name: 61F-G2N base * 1, 61F-11_ unit * 2.
Uses: 2 wire type. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 100 mm (wide view).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly SGE-225-0-0260L 05000C-05000C.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models .
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Sensing method: Retro reflective.
Appearance: Vertical.
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm [100 mm].
Model: NPN output.
Recommended application: Flat object,
Detecting glass wafers and LCD glass circuit boards, Ideal;
Cylindrical object,
Detecting plastic bottles and other transparent containers, Ideal.
Ideal for Detecting Glass Wafers,
and Other Transparent Objects,
Detects glass wafers and LCD glass circuit boards. Control terminal block: Terminal block with small slotted screws.
Type: Standard.
Capacity: 20 A, 100 to 240 VAC.
Heater burnout detection: No.
Communications: No.
High-precision Control with Easy Setup,
Precise heater burnout detection.
Set value and present value monitoring with indicators.
Phase control or opttimum cycle control SGE-225-0-0260L 05000C-05000C.
RS-485 communications to set manipulated variables and,
monitor load current.
Total run time monitoring.
Output modes for phase control: proportional to phase angle,
proportional to voltage, proportional to square voltage,,
and constant-current control SGE-225-0-0260L 05000C-05000C.
Application with various loads: constant load resistance,
variable load resistance.
UL, and IEC/EN (TÜV) certified.
SGE-225-0-0260L 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-0260L 05000C-05000C&select=5