Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- SGE-225-0-0850 00500C-00500C.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance
SGE-225-0-0850 00500C-00500C Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0 SGE-225-0-0850 00500C-00500C. 5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks .
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter SGE-225-0-0850 00500C-00500C.
Switch the PV display between three colors .
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. C500-OC I/O Unit Transistor Output 32 pts C500-OC224(3G2A5-OC224).
AC250/DC24V 2A.Pitch: 22 mm.
Applicable models: PYF08A.
Specifications: Max. carry current: 20 A (18 A at 70°C),
Ambient operating temperature: -40 to 70°C (with nocing or condensation),
Ambient operating humidity: 45% to 85% (with nocing or condensation),
Conductor material: Brass.
Conductor surface treatment: Nickel plating.
Package qty: 10/bag.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Control power supply voltage: 100/110 VDC.
Input: DC, Input voltage range, 10 to 300 V.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent usingg currennt converter SGE-225-0-0850 00500C-00500C.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrsee current detection SGE-225-0-0850 00500C-00500C.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
SGE-225-0-0850 00500C-00500C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-0850 00500C-00500C&select=5