Connects CQM1H to G730 SYSMAC BUS remote I/O
modules; max. 64 I/O (32 or 16 inputs or outputs, DIP switch selectable)
Number of I/O points per Master: 128
Communications cycle time: 187.5 kbps
Max. transmission distance: 200 m
One master and two expansions allowed per systemSize: 48 x 48mm.
Body: terminal type .
Type: control output 2 point type (power AC/DC24V) SGE-225-0-1500 00650C-00650C.
Shell color: black.
Control output 1: voltage output (SSR driver)
SGE-225-0-1500 00650C-00650C
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater SGE-225-0-1500 00650C-00650C.
Event input points: - .
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0 SGE-225-0-1500 00650C-00650C. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms .
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultType: Standard.
Sealing: Flux-tight.
Poles: 6 poles.
Contact configuration: 3PST-NO, 3PST-NC.
Rated voltage: 12, 18, 21, 24, 48, 110 VDC.
Compact, Slim Relays Conforming to,
EN Standards.
Relays with forcibly guided contacts,
(EN502205 Classs A, certified by VDE) SGE-225-0-1500 00650C-00650C.
Supports the CE marking of machinery (Machinery Directive).
Helps avoid hazardous machine status when used as part of,
an interlocking circuit.
Four-pole and six-pole Relays are available.
The Relay’s terminal arrangemmennt simplifies PWB pattern design SGE-225-0-1500 00650C-00650C.
Reinforced insulation between inputs and outputs.
Reinforced insulation between some poles of different polarity.
SGE-225-0-1500 00650C-00650C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-1500 00650C-00650C&select=5