Unit classification: CJ1 Special I/O Units.
Product name: Highspeed Counter Unit.
Specifications; Countable channels: 2 ,
Encoder A and B inputs, pulse input Z signals;
Open collector Input voltage: 5VDC, 12V, or 24V,
(5V and 12V are each for one axis only.) ,
Max. counting rate, 50kHz.
No . of unit numbers allocated: 4.
Current consumption: 5V, 0 SGE-225-0-2730 05000C-05000C. 28A; 24V, --.
Standards: UC1, N, L, CE
SGE-225-0-2730 05000C-05000C
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 Counters and counts ,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions SGE-225-0-2730 05000C-05000C.
The Unit is equipped with 2 Digital Inputs,
2 Digital Outputs and 30 Soft Outputs .
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Name: e-CON Connector Type.
Specifications: Analog outputs;
2 outputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet SGE-225-0-2730 05000C-05000C.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system .
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Sensing method: Distance-settable(BGS Models).
Connection method: Pre-wired (2 m).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color.
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Name: electrode with 5PP SGE-225-0-2730 05000C-05000C.
The installation and disassembly are very simple and can be used in deep wells .
The electrode is a stainless steel wire with a layer of vinyl chloride, and the electrode is not in contact with the electrode.
Can also be used in space such as sink annd ceiling SGE-225-0-2730 05000C-05000C.
Easy accumulation of deep well pump sewage, the scale can be used PH-1;
In the distance from the depth of the water use, can choose PH-2.
SGE-225-0-2730 05000C-05000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-225-0-2730 05000C-05000C&select=5