Model: PFA (front-mounting), page 24.
Approx: 57 g.
Number of pins: 8 pins.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available . Name: HFU with Programless Communications *1 SGE-245-2-0380 10000C.
Power supply voltage: 24 VDC supplied from the End Unit
SGE-245-2-0380 10000C
No. of control points: None.
Control outputs 1 and 2: None.
Control outputs 3 and 4: None.
Auxiliary output: Transistor output: 4 points (sinking).
Functions: burnout Heater alarm, None; Event inputs, 4.
Communications functions: Port C: RS-422,
From End Unit: Port A: RS-485 SGE-245-2-0380 10000C.
Input type: No input.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design SGE-245-2-0380 10000C.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,
requirements.
Connect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise.
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calculate the PID constants with the step,
response method.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
Setting range: 0.1 to 1 A AC/DC, 0.5 to 5 A AC/DC, 0.8 to 8 A AC/DC.
Power supply voltage: 100 to 240 VAC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CCTs (CT currentt on secondary,
side: 0 to 1 A or 0 to 5 A) SGE-245-2-0380 10000C.
Manual resetting and automatically resetting supported by one Relay.
Startup lock and operating time can be set separately.
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can bbe switched between normally open and normally closed SGE-245-2-0380 10000C.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply.
SGE-245-2-0380 10000C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-245-2-0380 10000C&select=5