Actuator: Roller lever (Metal lever, resin roller).
Cable length: 5 m.
Pull-outing direction of cable: Vertical.
Built-in switch: 2NC/2NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) .
High-sensitivity safety limit switch SGE-365-5-0830 02000C-02000F.
Built-in switches with two- or four-contact construction are available
SGE-365-5-0830 02000C-02000F
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Size: M12 (Brass); Single; Shielded.
Sensing distance: 5 mm SGE-365-5-0830 02000C-02000F.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN .
Operation mode NC.
A new generation in global applications. Appearance: ADR shell.
Circuit structure and open circuit mode: single contact 1C, voltage, no voltage, DC circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3 SGE-365-5-0830 02000C-02000F. 5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0 . 25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: closed circuit, 110V 5A L/R=0ms1000 DC220V times, 10A L/R=0ms1000 DC times;
30W (DC 110V 1A closed, L/R=25ms1000), 80VA (AC 220V 1A) cos with =0.1 1000.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of ffuzzy innference to make the protection and coordination of digital DCR SGE-365-5-0830 02000C-02000F.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme SGE-365-5-0830 02000C-02000F.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.
SGE-365-5-0830 02000C-02000F Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SGE-365-5-0830 02000C-02000F&select=5