Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NO.
A new generation in global applications. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 24 VAC/VDC .
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white
SP20-DT-A
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads SP20-DT-A.
Easy-to-wire terminal arrangement .
Certified for EN 60947-5-1. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work SP20-DT-A.
Ideal for the thermal input devices of Temperature Controllers .
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Insulation method: Photocoupler.
Operation indicator: Yes.
Response speed: High-speed.
Applicable load: 4 to 32 VDC 0.1 to 100 mA.
Input rated voltage: 12 to 24 VDC.
SSR with Plug-in Terminals.
The Same Shape as the G2R-1-S.
Power Relays.
These I/O solid state relays can be mounted in OMRON.
G70A I/O Terminals.
Lineup includes Input Modules for microloads and Output,
Modules for standard loads.
Lineup also includes UL, CSA, and TÜV-certified models,
(-UTU models). Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Pulse Input Unit.
Input points : 4 pulse inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.20A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,,
have enabled major savinngs in cost and space compared,
with previous systems SP20-DT-A.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems SP20-DT-A.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
SP20-DT-A Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=SP20-DT-A&select=5