LK166
Home >> Price >> OMRON >> V-154-2A5
Brand sort

OMRON V-154-2A5

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Model: V-154-2A5
Market price: U.S.$ 2.62
(The following are the market open price not sales price!)
next one: OMRON V-154-1E6
Last one: OMRON V-154-4A5
OMRON V-154-2A5
Actuator: Roller lever (resin lever, resin roller).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available V-154-2A5. )
M12-connector models are also available, saving on labor and,
simplifying replacement V-154-2A5
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC V-154-2A5. Input capacity: 16 points .
Internal I/O common: NPN.
ON voltage: 15 VDC min.
(between each input terminal and the V terminal)
OFF voltage: 5 VDC max.
(between each input terminal and the V terminal)
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC).
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0 V-154-2A5. 5 ms, 1 ms,
2 ms, 4 ms, 8 ms, 16 ms, 32 ms . (Default setting: 1 ms)
Number of circuits per common: 8 points/common.
Input indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply.
Input device supply current: 100 mA/point.
Unit power supply current consumption: 90 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
I/O power supply current consumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 370 g max.
Expansion functions: No.
Short-circuit protection function: No.
A common terminal is provided for each contact.
It eliminate the needs for relay terminal blocks.
It is unnecessary to shhare the common terminal,

among multiple contacts V-154-2A5.
Easy-to-find wiring locations.
Detachable screw terminal block facilitates the maintenance.
Input response time can be switched for high-speed processing.
Selectable node address setting methods: setting with rotary,

swwitch and with tool software V-154-2A5.
When setting the nodes with rotary switch, setting is easy and,
node identification becomes possible for maintenance.
V-154-2A5 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=V-154-2A5&select=5


...more relevant model market price >>>>
Related products
Related download