LK166
Home >> Price >> OMRON >> V680-HS63-R 2M
Brand sort

OMRON V680-HS63-R 2M

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Market price: U.S.$ 542.71
(The following are the market open price not sales price!)
OMRON V680-HS63-R 2M
Actuator: Steel wire (wire diameter: 1).
Item: Basic.
Pretravel (PT): 40±20 mm.
Select the Best Two-circuit Switch for the,
Operating Environment and Application,
from a Wide Range of Models,
A wide selection of models is available, including General-purpose,
Environment-resistant, and Spatter prevention Switches .
Standard-feature gold-clad crossbar contacts provide high reliability V680-HS63-R 2M.
Applicable to either standard loads or microloads V680-HS63-R 2M
Switches with Lever Actuators provide 90° overtravel,
one-side operation, and four-direction head mounting.
Approved standards: EN/IEC, UL, cUL, and CCC.
Contact your OMRON representative for information on approved models V680-HS63-R 2M. Head material: Plastic*1 .
Release key position: Bottom.
Release key type: Special release key(resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 2NC/1NO+1NC/1NO V680-HS63-R 2M.
Conduit opening: G1/2 .
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection.
Variety of Metallic Heads Available. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thhe state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV V680-HS63-R 2M.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation V680-HS63-R 2M.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
V680-HS63-R 2M Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=V680-HS63-R 2M&select=5


...more relevant model market price >>>>
Related products
Related download