Cable specifications: Fire-retardant, Robot cable.
Cable length L: 1 m.
Cable outer diameter: 6 mm.
Angled Connectors.
Minimum order: 10.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors .
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock V700-D23P32.
A positive click indicates locking
V700-D23P32
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Rated voltage: 200 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz V700-D23P32.
Rated rotational speed: 50 Hz, 2650 r/min; 60 Hz, 3000 r/min .
Maximum flow rate: 50 Hz, 3.5 m3/min; 60 Hz, 4.0 m3/min.
Maximum static pressure: 50 Hz, 68 Pa; 60 Hz, 63 Pa.
Noise: 50 Hz, 50 dB; 60 Hz, 53 dB.
Weight: Approx. 3410 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work V700-D23P32.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Internal I/O common: PNP.
I/O indicators: LED display (yellow).
Unit power supply current consumption: 120 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available at input,
section only (Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
staandard e-CON connectors V700-D23P32.
A common terminal is provided for,
each connector .
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary,
sswiitch and with tool software V700-D23P32.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance.
V700-D23P32 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=V700-D23P32&select=5