Size: Shielded, M30.
Sensing distance: 10 mm.
Model: Output configuration: NPN NO.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings.
Chemical resistance certified by Ecolab Europe .
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating
WLCA12-2G-N Type: With cable.
No. of poles: 4.
Lock: Rear lock.
Cable length: 0.5 m.
Minimum order: 10.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock WLCA12-2G-N.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Name: Basic Unit (temperature control) *1.
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Voltage output: 2 points (for SSR drive) *2 WLCA12-2G-N.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, 2 *3; Event inputs, 2 .
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: Screw-less clamp.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventorry,
requirements WLCA12-2G-N.
Conneect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise .
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method WLCA12-2G-N.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
WLCA12-2G-N Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=WLCA12-2G-N&select=5