Type: rectangle.
Screen mode: no segmentation.
Output: SPDT.
Power supply voltage: DC5V.
Contact type: standard load (AC250V, 3A; DC30V, 3A).
Operation: instantaneous action (auto reset).
Operation Department color: Red / green.
In the touch and the ability to protect than OMRON''s previous models have improved .
The micro volume design of 23mm is realized WLF6D2.
Micro design and unique combination of soft sensing
WLF6D2
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient WLF6D2. Isolation: Photocoupler.
Zero cross function: --.
Indicator: NO.
Rated output load: 3 A at 4 to 48 VDC (See note 2.).
Rated input voltage: 4 to 24 VDC.
International Standards for G3F Series,
Same Profile as MY Power Relays.
Shape-compatible with mechanical relays.
Certified by UL, CSA, and VDE (model numbers with a suffix of“-VD”).
Socket type, same size as MY Power Relays WLF6D2.
Operation indicator provided to confirm input.
(model numbers with “N” before the suffix). Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Type: open type.
Structure: DIN guide rail mounting type.
Capacity: 150W.
Output voltage: 5V.
Output current: 27A.
Built in OMRON''s original new under voltage detection function of small size,
Also contribute to the miniaturization of the device.
Built in support for determining the abnormal causes of the new under voltage detection function.
(S8VM- - P - 24A - racy type)
Power failure detection function with built-in hint output voltage abnormity.
(type 300/600/1500W)
A total of 8 kinds of capacity of 29 models, a complete range of products.
Meet RoHS instructions including lead free.
Humanized design of anti - shedding screw for terminal stage.
(exceept for the 300/600/1500W outpput terminals)
Support finger touch protection to prevent electric shock WLF6D2.
DIN guide rail simple installation.
Safety standards: CSA, C22.2 No.14/No.60950-1 UL508/60950-1,
EN50178, EN60950-1.
(300/600/1500W type, safety standard is not applicable whhenn the fan is replaced by the customer WLF6D2. )
Meet F47-0200 SEMI standards. (200V input)
High harmonic current limit: EN61000-3-2. (except for type 15/30W)
WLF6D2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=WLF6D2&select=5