Suitable cable dia: 4 mm dia. model (4 to 5 mm dia.).
Suitable core size: 0.18 to 0.3 mm; 0.5 to 0.75 mm.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Crimping.
DC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort .
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating
XC7C-9642-S003
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on XC7C-9642-S003.
Connectors with Cables are UL certified .
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
No output: -.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
To support the sensor input, the pressure, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified XC7C-9642-S003.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Can enter DC0.001mInput terminals: Compact slotted screw terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 25 A, 100 to 240 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters XC7C-9642-S003.
Detects thhe burnout of 3-phase heaters .
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termiinaals (detachable), or compact slotted,
screw terminals (detachable) XC7C-9642-S003.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
XC7C-9642-S003 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XC7C-9642-S003&select=5