Appearance: Round/Flat without Voltage Reduction Unit M22-F.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Round Indicator Series with 22 dia. and.
25 dia. (when using a ring).
Same type as the A22-series Pushbutton Switches .
Use 25-dia. ring to install in 25-dia XG8V-2041. panel cutouts.
IP65. Improved update. Reduce standby power consumption, and then achieve lightweight
XG8V-2041
Standby power consumption reduced to 85% of the company''s previous products. (61F-GN)
The quality is reduced to less than 85% of the company''s previous products. (61F-G3N, G4N)
With LED action display function, so that the state of action at a glance XG8V-2041.
By improving the reliability of internal relays (tiny load 1mA DC5V), the PLC input becomes possible.
The electrode side terminals and other wiring terminals are separated, so the wiring operation is simple.
Installation method can choose the JEM agreement, DIN guide rail installation, screw installation in 3 ways.
G4N type, with a water tank and a water supply tank level display and prevent the function of automatic water idling caused by water shortage XG8V-2041.
Package product name: 61F-G4N base * 1, 61F-11_ unit * 5.
Purpose: long distance use (2km). Appearance: Square/Projection without Voltage Reduction Unit M22-C.
Lighting: LED.
Operating voltage: 6 VAC/VDC.
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Round Indicator Series with 22 dia. and.
25 dia. (when using a ring).
Same type as the A22-series Pushbutton Switches.
Use 25-dia. ring to install in 25-dia. panel cutouts.
IP65. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to ssee the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV XG8V-2041.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation XG8V-2041.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
XG8V-2041 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XG8V-2041&select=5