Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work .
Ideal for the thermal input devices of Temperature Controllers
XS2C-D4S4
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Type: H5CX-B series.
Time specifications: 0.01 to 9999.99 s, 1 s to 99 h 59 min 59 s,
0 XS2C-D4S4. 1 to 99999.9 min, 0.1 to 99999 . 9 h.
Operating modes: A: Signal ON Delay I, F-1: Cumulative.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output (DPST).
Supply voltage: 12 to 24 VDC.
The Timer with the Shortest Body,
in the Industry. Actuator: General purpose; Crossroller plunger; AC.
Mounting: Base mounting.
Approved standards: UL CSA XS2C-D4S4.
General-purpose Enclosed .
Switches with High Breaking.
Capacity and High Durability.
Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high,
breaking capacity.
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added,
to the series.
Three mounting methods (side, base, and diagonal side),
and many types of actuator are available.
Terminals face the front when the cover is removed for,
easy connection.
Switches with ground terminals have CE marking.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: output (using control output).
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the ppreventive maintenance funcction is increased,
Further performance improvement XS2C-D4S4.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV XS2C-D4S4.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
XS2C-D4S4 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS2C-D4S4&select=5