Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms .
(Slow-action models with MBB contacts are available XS2F-D421-DD0. )
M12-connector models are also available, saving on labor and,
simplifying replacement
XS2F-D421-DD0
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC XS2F-D421-DD0. Operating: Appearance, 40-dia . head Medium Push-lock Turn-reset With EMS, Indication; Contact Configuration, 3NC (1NC + 1NC + 1NC) .
Color of cap: Red.
Install in 22-dia. or 25-dia. Panel Cutout.
Direct opening mechanism to open the circuit when the contact welds.
Safety lock mechanism prevents operating errors.
Easy mounting and removal of Switch Blocks using a lever XS2F-D421-DD0.
Mount three Switch Units in series to improve wiring efficiency,
(with non-lighted Switch Units, three Units can be mounted for,
multiple contacts) .
Finger protection mechanism on Switch Unit provided as a,
standard feature.
Install using either round, or forked crimp terminals.
Oil-resistant to IP65 (non-lighted models)/IP65 (lighted models),
A lock plate is provided as a standard feature to ensure that the,
control box and switch are not easily separated. Installation method: surface mount.
Action function: 8 multi-function action (A, B, C, D, E, F, G, H,).
Action mode / reset mode: time limit action / auto reset / external reset.
Set lock mechanism.
External connection: terminal with screw.
Time limit contact: 1c.
Instantaneous contactt: No XS2F-D421-DD0.
1 timer to achieve AC/DC free power,
8 action functions 0.1 seconds to 9990 hours.
Through time display windows wide, eye-catching.
Free power mode using AC24 ~ 240V/DC12 ~ 240V.
And the DC specification does not have to specify the pollarrity XS2F-D421-DD0.
8 action functions can be selected by the action function switch.
Combined operation of time setting switch and time unit switch,
Realization