Actuator: Roller lever (Metal lever, resin roller).
Cable length: 5 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 1NC/1NO (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) .
High-sensitivity safety limit switch XS2H-D421-C80-F.
Built-in switches with two- or four-contact construction are available
XS2H-D421-C80-F
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; M20 XS2H-D421-C80-F.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action) .
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability XS2H-D421-C80-F.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Model: DSR (67S).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generrator and the electriic side / internal tributaries XS2H-D421-C80-F.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiinee the direction of the sudden drop in the voltage to 0 of the short-circuit accident XS2H-D421-C80-F.
2 stage cross terminal stand with cover with convenient wiring.
XS2H-D421-C80-F Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS2H-D421-C80-F&select=5