Setting range: 2 to 20 mA AC/DC, 10 to 100 mA AC/DC, 50 to 500 mA AC/DC.
Power supply voltage: 24 VAC/DC.
Ideal for Current Monitoring for.
Industrial Facilities and Equipment.
Monitor for overcurrents or undercurrents.
Use commercially available CTs (CT current on secondary,
side: 0 to 1 A or 0 to 5 A) .
Manual resetting and automatically resetting supported by one Relay XS5H-D421-B80-CL3.
Startup lock and operating time can be set separately
XS5H-D421-B80-CL3
One SPDT output relay, 5 A at 250 VAC (resistive load).
Output relay can be switched between normally open and normally closed.
Output status can be monitored using LED indicator.
Inputs are isolated from the power supply XS5H-D421-B80-CL3. Type of drive rod: plunger type.
Conduit size: single catheter type, M20 .
Built in switch structure: slow motion (1NC).
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forced open action structure.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm XS5H-D421-B80-CL3.
Elevator and escalator can be used. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Manual.
Output: SPST-NC.
Operating voltage: 100 VAC.
Illumination color: R (red); Y (yelllow); G (green); AA (blue) XS5H-D421-B80-CL3.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounttedd using either open-type (fork-type) or closed-type,
(round-type) crimp terminals XS5H-D421-B80-CL3.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).
XS5H-D421-B80-CL3 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XS5H-D421-B80-CL3&select=5