Size: M12, Shielded.
Sensing distance: 4.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 56 (72).
Output configuration: NPN.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor XW2B-S012.
Problems such as the collision of workpieces are eliminated
XW2B-S012
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 x 48mm.
Body: terminal type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver) XW2B-S012.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: -.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products XW2B-S012.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance .
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultThe main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the prevenntive maintenance function is increased,
Further performance improvement XW2B-S012.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV XW2B-S012.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
XW2B-S012 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XW2B-S012&select=5