Standard certification: No.
Action indicator: No.
Applicable load of output: AC100 3A ~ 240V.
Input rated voltage: DC24V.
Insulation mode: three end two-way photoelectric switch.
Zero crossing trigger function.
And the MY type of the same shape of the G3F series of new international standard certification (-VD type) .
Achieved UL, CSA, EN (VDE certification) standard certification XW2Z-0500U-6. (type -VD)
Socket terminal type of same size with MY (2 pole type)
XW2Z-0500U-6
A model with an action indicator to check the status of the input. I/O Cable (for Rack I/O to Backplane) 0.4 m (L) CV500-CN413Sensor type and wiring: 3-wire DC NPN/2-wire DC 3-4.
Actuator wiring: Actuator wiring 1-4 XW2Z-0500U-6.
No. of ports: 4.
No . of I/O: 4.
Simple Wiring of Sensor Actuators.
Greatly reduce wiring in combination with the Smartclick XS5.
Insert the connector and turn 1/8 of a turn to lock the connectors.
Higher rated current to enable output applications.
Use previous M12 screw connectors. Release key type: Special release key.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release XW2Z-0500U-6.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC .
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Applicable Current Transformer.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater controol methods,
including OON/OFF control, phase control, and cyclic control XW2Z-0500U-6.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurreentt relay or for motor or lamp loads XW2Z-0500U-6.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@).
XW2Z-0500U-6 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XW2Z-0500U-6&select=5