Drive rod: R type swing lever type.
Specifications: plastic wire terminal.
The protection structure is in conformity with the JIS''s anti immersion type, IP67 IEC (except for the terminal part).
Can be used in the environment temperature -40 ~ +85.
Through the use of gold alloy bar, contact springs to achieve longevity and high contact reliability XW2Z-100J-A30. Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage
XW2Z-100J-A30
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.087 A; 60 Hz, 0.075 A .
Rated input: 50 Hz, 12 W; 60 Hz, 11 W.
Rated rotational speed: 50 Hz, 2500 r/min; 60 Hz, 3000 r/min.
Maximum flow rate: 50 Hz, 0.5 m3/min; 60 Hz, 0 XW2Z-100J-A30. 6 m3/min.
Maximum static pressure: 50 Hz, 34 . 0 Pa; 60 Hz, 49.0 Pa.
Noise: 50 Hz, 33 dB; 60 Hz, 36 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series XW2Z-100J-A30.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series .
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Element type: K (CA).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 15 dia.
Protective tubing length L: 100 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Enclosed-terminal Models.
Protective tubing length L: 35cm.
Protective tubing diameter D (mm): 3.2 dia.
A WWide Variety of High-prrecision XW2Z-100J-A30.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teempperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal XW2Z-100J-A30.
XW2Z-100J-A30 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XW2Z-100J-A30&select=5