Number of beams: 60.
Protective height: 1200mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions.
Series connection is possible only with the MSF4800A .
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module
XW4A-09B1-V1
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Applicable CPU Units: CQM1H-CPU51/61 XW4A-09B1-V1.
Connection location and number of Units: One Unit only . The Unit must be connected between the Power Supply Unit and the CPU Unit.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 170 g max.Output: DPDT.
Lighting: LED (with built-in reduced-voltage lighting function).
Operating voltage: 200/220 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; PW: pure white; B: black *2 XW4A-09B1-V1.
Item: Alternate operation (Self-holding) .
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV XW4A-09B1-V1.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation XW4A-09B1-V1.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
XW4A-09B1-V1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=XW4A-09B1-V1&select=5