LK166
Home >> Price >> OMRON >> XW4E-08C1-S1
Brand sort

OMRON XW4E-08C1-S1

No PHOTO
Brand: OMRON
Country: JAPAN
Name:
Model: XW4E-08C1-S1
Market price: U.S.$ 8.87
(The following are the market open price not sales price!)
OMRON XW4E-08C1-S1
Supply voltage: 100 or 230 V AC (selectable), 50/60 Hz.
Operating voltage range: 85 to 265 V AC.
Output capacity: 5 V DC: 6 A 24 V DC: 0.5 A(30 W total, see note).Power rating: 25 W.
Input voltage: 100 to 240 VAC (allowable range: 85 to 264 VAC or 120 to 370 VDC*1).
Output voltage: 15 V VDC.
Output current: 1 . 7 A.
Built-in fan: None XW4E-08C1-S1.
Model with terminal block facing forward.
High Reliability at a Reasonable Cost XW4E-08C1-S1
Reliable, Basic Power Supplies That,
Contribute to Stable Equipment Operation.
High Reliability: Enhanced abnormal overvoltage,
resistance and lightning surge resistance for stable,
operation even with an unstable input voltage XW4E-08C1-S1.
Long Life: Japanese 105°C electrolytic capacitors are used,
to achieve stable quality and long life . A reliable 3-year warranty.
Wide Input Ranges: 100 to 120 VAC and 200 to 240 VAC,
Full Lineup: Models are available for the main output,
voltages and capacities used in FA applications.
Global Standards: Conforms to CE (all models),
Approved for UL (all models) and CCC (15 to 150-W models) XW4E-08C1-S1.
Easy mounting to DIN Rails with Mounting Brackets (sold separately) .
Refer to Period and Terms of W. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 4.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: -.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV statuus display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV XW4E-08C1-S1.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput XW4E-08C1-S1.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
XW4E-08C1-S1 Operation manual / Instructions / Catalog download link: /searchDownload.html?Search=XW4E-08C1-S1&select=5


...more relevant model market price >>>>
Related products
Related download