Output: SPDT.
Lighting: Incandescent lamp.
Operating voltage: 12 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28 . 5 mm, the smallest class in the industry Z-15GW2-B.
Detachable Switch.
The same contacts can be used for both standard loads and microloads
Z-15GW2-B
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Number of beams: 22.
Protective height: 440mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series Z-15GW2-B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions .
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions Z-15GW2-B. Type: Narrow View.
Setting distance: 34 to 49 mm (variable).
Sensing area: 5 x 4.6 mm to 9 x 8.3 mm (variable).
Degree of protection: IP65.
Simple to use.
Detection abilities close to human vision.
One-touch automatic setting for stable detection.
2.2-inch monitor integrated in compact housing.
Sensor Heads with field of view up to 150 mm. Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set ttime value can be checked eeasily because operation time,
is indicated from the start of operation Z-15GW2-B.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeenccy, basic,
frequency, and load conditions Z-15GW2-B. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
Z-15GW2-B Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=Z-15GW2-B&select=5