Unique Ratchet Mechanism Assures Positive.
Alternate Transfer/Switching Operation.
Each contact in the double-pole contact mechanism performs.
alternate make-brake operation at each pulse input and is thus.
ideal for alternate operation or transfer/switching operation of a motor.
Positive operation is assured due to the unique ratchet mecha nism G3S-201PL-PD-US DC12.
Satisfies dielectric strength of 2,000 VAC.
Low power consumption
G3S-201PL-PD-US DC12
(AC: approx. 6.4 VA; DC: approx. 3.9 W). Rated voltage: 200 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.050 A; 60 Hz, 0.040 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W G3S-201PL-PD-US DC12.
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min .
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25.0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation G3S-201PL-PD-US DC12.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series .
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,
the information in Characteristics. Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard.
Auxiliary output points: -.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive mmaintenance funcction is increased,
Further performance improvement G3S-201PL-PD-US DC12.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivve display PV/SV G3S-201PL-PD-US DC12.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
G3S-201PL-PD-US DC12 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G3S-201PL-PD-US DC12&select=5