Number of beams: 29.
Protective height: 720mm.
Model: NPN output.
Basic Type with a combination of.
performance and functionality.
Up to three sets of series-connected sensors.
The muting function is enabled simply with Muting Key Cap.
Comes standard with interlock and auxiliary output functions . Ontology: terminal type, analog input type G7J-2A2B-T AC50.
Category: control output 2 point type (power supply AC100 ~ 240V)
G7J-2A2B-T AC50
Shell color: black.
Control output 1: current output.
Control output 2: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use G7J-2A2B-T AC50.
Event input points: - .
Transfer output: output (using control output).
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type G7J-2A2B-T AC50.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Output: DPDT.
Lighting: Incandescent lamp.
Operating voltage: 5 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 2 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance perfformance G7J-2A2B-T AC50.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set G7J-2A2B-T AC50.
It can be easily set by CS-Thermo (sold separately).
G7J-2A2B-T AC50 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G7J-2A2B-T AC50&select=5