Classification: Preset Counter.
Input signal system (Count & reset inputs): Contact, Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high), Up indicator.
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: No.
Control output: Transistor (opencollector) .
Operating mode: Down counting G7L-1A-TUB DC6.
Max.counting speed: 5 kcps (see note 1
G7L-1A-TUB DC6).
All Required Counter Functions.
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter G7L-1A-TUB DC6.
Power supply freely selectable within a range of 100 to 240 VAC .
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling G7L-1A-TUB DC6.
Auxiliary output points: 2 points .
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, connvenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV G7L-1A-TUB DC6.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact ouutput G7L-1A-TUB DC6.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
G7L-1A-TUB DC6 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=G7L-1A-TUB DC6&select=5