Cable with connector (1 to 2) /G79-O_C-_, G79-I_C-_.
L size: A, 5000mm; B, 4750mm.
Output use
Cable and loose wire cable with loose wire pressing connecting terminal,
Connector cable, MITSUBISHI motor produced PLC connection cable. Type: Monochrome; NPN; EtherCAT communication function not provided.
Key features and benefits .
Made specifically for pick & place,
applications GRT1-OD8-1.
Encoder input for conveyor tracking,
and calibration
GRT1-OD8-1
Shape based object detection.
Smart calibration wizard.
Sysmac Studio software for vision.
system operation and setting. Modular panel direct mounting type, easy to install and maintain the basic type.
The relay unit is modular and easy to maintain GRT1-OD8-1.
With LED action display function, so that the state of action at a glance .
Tropical treatment and high temperature.
Stable detection can be achieved with high ambient temperature.
Type: I type, water level display and alarm (No 2 wire in I).
Package product name: 61F-I base * 1, 61F-11_ unit * 2.
Purpose: high temperature. Output: DPDT.
Lighting: LED without Voltage Reduction Unit GRT1-OD8-1.
Operating voltage: 24 VAC/VDC .
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Type: Reverse wiring.
Cable length L: 1.0 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Operation indicator: Without operating indication; Standard load.
Ratings: 5 A at 250 VAC; 4 A at 30 VDC.
Actuator: Adjustable rod lever.
Cable length : 3m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrancce sealed via encapsulatinng material GRT1-OD8-1.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
conffirrmation of operation GRT1-OD8-1.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
GRT1-OD8-1 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=GRT1-OD8-1&select=5