No. of steps: 6.
Rated voltage: 24 VDC, 100 VAC, 200 VAC.
Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without .
power. All internal contacts are released when no power is supplied H2F-DC AC200/220/240.
Detects an internal element malfunction caused by external
H2F-DC AC200/220/240
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannot be detected.).
With safety-design terminals which prevent electric shock accidents H2F-DC AC200/220/240.
With easy-to-see indicators which display the stepping status . No. of poles: 4.
Connection method: Soldering.
Suitable cable dia: 3 mm (3 to 4).
Core conductor size: 0.5 max.
Suitable sheath material: PVC, PE, PUR.
Straight Connectors.
Minimum order: 50.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors H2F-DC AC200/220/240.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 6.4 dia.
Protective tubing length L: 50cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Logical AND Function Adds Flexibility to I/O Expansion.
Facilitates partial or compplete control syystem setup H2F-DC AC200/220/240.
Solid-state outputs (excluding Expansion Units).
Detailed LED indications enable easy diagnosis.
TÜV SÜD certification for compliance,
with IEC/EN61508 (SIL3), EN ISO13849-1 (PLe/Safety Category 4).
Approved by UL and CSA.
New unnitt joins the Series with the following two additional features:
-OFF-delay time of up to 150 seconds can be set H2F-DC AC200/220/240.
-Two logical AND connection inputs.
H2F-DC AC200/220/240 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=H2F-DC AC200/220/240&select=5