Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch.
The same contacts can be used for both standard loads and microloads H3CR-HRL AC200-240 S.
Easy-to-wire terminal arrangement
H3CR-HRL AC200-240 S
Certified for EN 60947-5-1. Type: Shielded.
Appearance: Screw, M10 × 22 mm.
Sensing distance: 2 mm.
Repeat accuracy: 2 μm.
Cable specification: Standard .
Proximity Sensor with Separate.
Amplifier Enables Easily Making High H3CR-HRL AC200-240 S.
precision Sensitivity Settings .
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. models).
Make simple and reliable detection settings with micron,
level precision using the teaching function H3CR-HRL AC200-240 S.
Check the sensing excess gain level on the digital display .
Support for high-precision positioning and screening with,
fine positioning to maximize variations.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit. Unit type: CS1 Basic I/O Units.
Product name: Relay Output Units.
Specifications:12 to 24 VDC,
0.5A 32 outputs; Sinking.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 2 words.
Current consumption: 5V system, 0.27A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Size: M18, Shielded.
Sensing distance: 8.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall lengthh): 61 (81) H3CR-HRL AC200-240 S.
Ouutput configuration: NPN .
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpiecees are eliminated H3CR-HRL AC200-240 S.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization.
H3CR-HRL AC200-240 S Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=H3CR-HRL AC200-240 S&select=5