Output: DPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; Non-lighted.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch.
The same contacts can be used for both standard loads and microloads H3FA-BU DC24.
Easy-to-wire terminal arrangement
H3FA-BU DC24
Certified for EN 60947-5-1. Suitable cable dia: 6 mm dia. model (5 to 6 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: L-shaped.
Connection method: Soldering.
DC: Model H3FA-BU DC24.
Minimum order: 50.
Water- and Environment-resistive FA .
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on H3FA-BU DC24.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. Product name: CJ2H (Built-in EtherNet/IP) CPU Units.
Specifications: I/O capacity/Mountable Units(Expansion Racks),
2,560 points/40 Units(3 Expansion Racks max.) ;
Program capacity, 150K steps; Data memory capacity,
352K words(DM: 32K words, EM: 32K words × 10 banks);
LD nstructio execution time, 0.016 μs.
Current consumption(A): 5V,0.82(See note.); 24v, --.
Standards: UC1, N, L, CE.
CJ2H for high speed, high capacity.
The CJ2H Series is ideal for advanced machine.
automation needs such as those required in image.
processing inspection of electrical components and,
high speed sorting on conveyors. Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 macchines to support a variety of sensorss H3FA-BU DC24.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eeexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
H3FA-BU DC24 Operation manual / Instructions / Catalog download link: