Detection mode: diffuse reflection type.
Connection: socket type (M12).
Detection range: red light 1mmmm.
Output mode: PNP output. Name: Temperature Control Module.
Model: C200H-TC002.
Sensor: Thermocouple: R, S, K(CA), J(IC), T(CC), E(CRC), B, N, L(IC), U(CC).
Control output: Voltage output.Name: Compact Connectors .
Specifications: Outputs; 2 outputs; PNP H3Y-2-C AC220V 30M.
Bit slave of smallest class in industry,
Innovation in wiring for any type of machinery
H3Y-2-C AC220V 30M
Available in 2 types: 2-point Bit Slave Unit,
and 4-point Bit Slave Unit.
Compact size for installation in limited space.
Save space and wiring since bit slave can be,
installed near I/O devices H3Y-2-C AC220V 30M.
Industry first bit slave connectable with round,
cables which can be easily purchased at a lower price .
Connectable with flat cables, too for easy wiring.
Cables are selectable depending on applications. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling H3Y-2-C AC220V 30M.
Auxiliary output points: 2 points .
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Name: Expansion Units e-CON Connector type.
Specifications:Digital inputs and outputs;
4 inputs/ 4 outputs; PNP;
One Expansion Unit can be mounted to one,
CRT1-VAD02@@D or CRT1-VDA02@@D Analog I/O Slave Unit.
Standards: --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made witth CompoNet H3Y-2-C AC220V 30M.
Wiriing material cost can be reduced .
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee . H3Y-2-C AC220V 30M.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.
H3Y-2-C AC220V 30M Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=H3Y-2-C AC220V 30M&select=5