The main body: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: relay output.
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function
H7BR-BV AC100-240 50/60HZ
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement H7BR-BV AC100-240 50/60HZ.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay H7BR-BV AC100-240 50/60HZ. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change .
Can be similar to the feeling of a limit switch installation.
Type: detection of variable terminal plate / DC type.
Shape: non shield.
Detection range: 30mm.
Output form: NO PNP + NC (dual output). Contact type: Standard load (250 VAC, 2 A; 125 VDC 0.4 A).
Operation: Alternate operation (Self-holding).
Output: DPDT.
Lighting: LED, 24 VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton
n @. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Shape of box: Without flange.
Actuator: Roller plunger (with a 6.8-dia. roller).
Conduit: Two on the side.
A New Monoblock Multiple Limit Switch.
Incorporating a Head Box with a Tough.
Head and Ensuring High Sealling H7BR-BV AC100-240 50/60HZ.
Perfformance and a Mechanical .
Durability of 5,000,000 Operations.
Used for the sequential control of a variety of engineering.
machines and belt conveyor lines.
Built-in oil filter shuts out oil and water.
Approved by EN, IEC (Ground terminal moddells only H7BR-BV AC100-240 50/60HZ. ) and,
CCC (Chinese standard). Ask your OMRON representative,
for information on approved models.
Ground terminal models bear the CE mark.
H7BR-BV AC100-240 50/60HZ Operation manual / Instructions / Catalog download link: