Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block .
No. of unit numbers allocated: 1 ITNC-DL1Q-E10L.
Current consumption: 5V, 0.12A; 26V, 0
ITNC-DL1Q-E10L12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value ITNC-DL1Q-E10L.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems ITNC-DL1Q-E10L.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCUs,
to construct complete process control systems.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
havve enabled major savinngs in cost and space compared,
with previous systems ITNC-DL1Q-E10L.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUss,
to construct complete process control systems ITNC-DL1Q-E10L.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.
ITNC-DL1Q-E10L Operation manual / Instructions / Catalog download link: