Output: SPDT.
Lighting: LED.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry .
Detachable Switch K2VU-S1-F4 110V.
The same contacts can be used for both standard loads and microloads
K2VU-S1-F4 110V
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Classification: Momentary operation.
Shape of Operation Unit: 36 dia. 25 dia.
Output: 2.
Operation Unit color: Blue (-A).
Long Service Life with Built-in Z-series K2VU-S1-F4 110V.
Basic Switch.
Using a Basic Switch enables direct switching of large-capacity loads .
Shock-absorbing construction of Operation Unit protects the Switch.
Drip-proof Pushbutton construction enables use in locations subject to,
splashing water and oil and scattering dust.
Pushbuttons are available in three shapes and six colors. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: SJT(O) cable *3 K2VU-S1-F4 110V.
Actuator: Roller lever, high sensitivity .
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see thee state of the thermoostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV K2VU-S1-F4 110V.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann ddisplay the current value / target / operation K2VU-S1-F4 110V.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.