Appearance: Unshielded, M12.
Sensing distance: 4 mm.
Output configuration: AC 2-wire.
Model: Operation mode, NO.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Pitch: 29 mm.
Applicable models: PYF14A .
Specifications: Max. carry current: 20 A (18 A at 70°C),
Ambient operating temperature: -40 to 70°C (with noicing or condensation),
Ambient operating humidity: 45% to 85% (with noicing or condensation),
Conductor material: Brass
K3FK-TS-1A-C
Conductor surface treatment: Nickel plating.
Package qty: 10/bag.
A Wide Variety of Square and,
Round Sockets in Front-mounting,
and Back-mounting Models,
Models available with finger protection K3FK-TS-1A-C.
Hold-down Clips and Socket Bridges for PYF Sockets,
are also available.
New screwless models available. Type: 1A contact type.
Shape: round.
Terminal shape: terminal for printed board.
Action: instantaneous.
Display mode: LED display.
Operation Department color: yellow.
Large capacity compact type push button switch K3FK-TS-1A-C.
Can also be used as a power switch with a large capacity cut .
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Power supply voltage: 12 to 24 VDC.
Output configuration: Open-collector output (PNP).
Output code: Gray.
Resolution (divisions): 256, 360, 720, 1,024.
Connection method: Pre-wired Model (1 m).
Rugged Rotary Encoder.
Absolute model.
External diameter of 50 mm.
Resolution of up to 1,024 (10-bit).
IP65 (improved oil-proof protection with sealed bearings).
Optimum angle control possible in combination with PLC or,
Cam Positioner. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked eaasily because operation time,
is indicated from the start of operation K3FK-TS-1A-C.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, annd load conditions K3FK-TS-1A-C. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.