The main body: with shell type / socket terminal type.
Classification: arc barrier built-in type.
Pole number: 3 pole.
A variety of eight pin pin type electric power.
With shell models have AC4 rated specifications (50/60Hz AC200/220V, 50/60Hz AC100/110V).
Installation, wiring convenient, easy to operate .
Has more than 5 million mechanical life, durable K3FS-RVS-A-C.
Standard type, with shell type, special contact specifications, double contact type, double coil latch type, etc
K3FS-RVS-A-C, the product is complete. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4.8 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 4m K3FS-RVS-A-C.
A Wide Variety of High-precision .
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal K3FS-RVS-A-C. Suitable cable dia: 4 mm dia . model (4 to 5 mm dia.).
Suitable core size: 0.5 max.
Suitable Sheath material: PVC, PE, PUR.
Cable connection direction: Straight.
Connection method: Soldering.
AC: Model.
Minimum order: 50.
Water- and Environment-resistive FA.
Connectors Save Wiring and Maintenance Effort.
Compact FA connectors meet IP67 requirements and ensure a,
94V-0 fire retardant rating.
A wide array of connectors makes a wiring system more modular,
simplifies maintenance, and reduces downtime.
Connectors with Cables and Connector Assemblies are available.
Three types of Connector Assembly: Crimping, soldering, and screw-on.
Connectors with Cables are UL certified.
Based on IEC61076-2-101 (IEC60947-5-2) and NECA 4202. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventivve maintenance function is increased,
Further performance improvement K3FS-RVS-A-C.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee ddisplay PV/SV K3FS-RVS-A-C.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
K3FS-RVS-A-C Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3FS-RVS-A-C&select=5