Continuation of the E6B2 high cost, value also have more choice.
E6B3, E6C4 blockbuster debut! Complementary output of the first starting high anti interference.
40mm diameter, shaft diameter of phi 8mm universal, with strong axial load capacity.
50mm diameter, shaft diameter of phi 10mm rugged, with strong axial load capacity,
At the same time, the use of IP65 anti drip, anti oil structure K3NC-PB1A-FLK3.
E6B2 complementary output will be issued over the same period
K3NC-PB1A-FLK3
Connection length to reach a full 30m!
Resolution (pulse / rotation):10~3600P/R.
Power supply voltage: DC12 ~ 24V
Consumption current: 100mA below.
Output state: complementary output.
Maximum response frequency: 100kHz K3NC-PB1A-FLK3.
Output phase difference: A phase, B phase difference 90 plus or minus 45 .
Starting torque: M / 10mN below (at room temperature).
Maximum allowable speed: 5000r/min.
Axial force: radial...... 120N, axial...... 50N. Number of beams: 40.
Protective height: 800mm.
Safety Light Curtains with Durable,
Impact-resistant Body and Long,
20-m Sensing Distance.
MS/MSF4800A Advanced Series K3NC-PB1A-FLK3.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions .
Series connection is possible only with the MSF4800A.
Blanking can be set.
Muting is possible only with the MSF4800A by using the,
MS4800-RM6 Resource Module.
MS/MSF4800B Basic Series,
Features all necessary basic Safety Light Curtain functions.
Series connection is possible only with the MSF4800B.
Programming and Diagnostics Module (PDM) makes it easy,
to set functions. Structure: Relays with Plug-in Terminals, With operation indicators.
Classification: Models with CR circuits for coil surge absorption,
(AC coil specification only).
Number of poles: 2 Bifurcated.
Power-switching Compact.
General-purpose Relays.
The standard models include models that are,
compliant with the UL, CSA, and SEV safety.
standards and with the Electrical Appliances and,
Material Safety Act.
Equipped with an arc barrier for arc interruption.
Withstand voltages up to 2,000 V.
New built-in diode and built-in CR circuit models have,,
joined the series K3NC-PB1A-FLK3.
The lineup also includes models that are compliant,
with the LR and VDE safety standards .
Single-pole and double-pole models have AC4,
ratings and DC2 ratings (operating coil ratings:
100/110 VAC, 110/120 VAC, 200/220 VAC, 220/240 VAC,
and 11000/110 VDC) K3NC-PB1A-FLK3.
Three-pole and four-pole models have AC4 ratings,
and DC2 ratings (operating coil ratings: 100/110,
VAC, 200/220 VAC and 100/110 VDC).
K3NC-PB1A-FLK3 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3NC-PB1A-FLK3&select=5