Input terminals: Screwless clamp terminals (detachable).
Isolation method: Phototriaccoupler.
Zero cross function: Yes.
Operation indicator: Yes.
Alarm output: 2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection).
Applicable load (See note.): 2 to 35 A, 100 to 240 VAC.
A New-concept SSR with Built-in .
Current Transformer K3NV-LC1A-B2.
Heater Burnout and SSR Short.
circuit Failure Detection
K3NV-LC1A-B2
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaters.
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch K3NV-LC1A-B2.
Mounts to a DIN track or with screws .
Three types of input terminals available: M3 terminals,
screwless clamp terminals (detachable), or compact slotted,
screw terminals (detachable).
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Sealed pin plunger.
Cable length : 3 m K3NV-LC1A-B2.
Compact Limit Switch That''s Also .
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Specification: three phase 400V.
Power: 90KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 89 kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the appliication field more extennsive K3NV-LC1A-B2.
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software. .
DeviceNet correspondence correspondence K3NV-LC1A-B2.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function.
K3NV-LC1A-B2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3NV-LC1A-B2&select=5