Cable specifications: Fire-retardant, Robot cable.
Cable length L: 2 m.
Cable outer diameter: 6 mm.
Straight Connectors.
Minimum order: 5.
UL: Yes.
Round Water-resistive Smartclick.
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors .
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock K3NX-VA1A-C2.
A positive click indicates locking
K3NX-VA1A-C2
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved. Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *) K3NX-VA1A-C2.
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC .
(DC power cannot be input.).
Power ratings: 50 W.
Output voltage: 12 V.
Output current: 4.2 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V).
Easy Mounting: Front-mounted type, DIN rail-mounted type are available.
Screw-mount at the top. (except 300-/600-W models) K3NX-VA1A-C2.
Safety standards: UL 508/60950-1, cUL CSA C22 . 2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA).
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Size: 48 x 24mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover).
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: -.
Event input: 2 points.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance.
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10.5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improvves the maintenance perfformance K3NX-VA1A-C2.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication.
The use of electric communication converrsiion Village (sold separately) connected to the computer after,
No power connection can be set K3NX-VA1A-C2.
It can be easily set by CS-Thermo (sold separately).
K3NX-VA1A-C2 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=K3NX-VA1A-C2&select=5