Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M12 connector.
Body material: Stainless steel.
Thread length (overall length): 27 (43).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor KM50-C1-FLK.
Problems such as the collision of workpieces are eliminated
KM50-C1-FLK
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; M12 connector.
Built-in switch mechanism: 1NC/1NO (Slow-action) KM50-C1-FLK.
A Series of Pull-reset Models Now .
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads KM50-C1-FLK.
Conforms to EN115, EN81-1 and EN81-2 .
Certified standards: UL, EN (TÜV), and CCC. Appearance: Rectangular (M16-A).
Lighting: Incandescent lamp, 24 VAC/VDC.
Degree of protection: IP65 oil-resistant.
Display color symbol: R: red; Y: yellow; G: green; A: blue;
W: white; PY: pure yellow; PW: pure white.
Cylindrical 16-dia. Indicator.
Same basic design as the A16 Pushbutton Switch. Type: H5CZ.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reeliability KM50-C1-FLK.
Power supplyy circuit and input circuits are isolated for safety and reliability .
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,,
the load KM50-C1-FLK.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
KM50-C1-FLK Operation manual / Instructions / Catalog download link: