Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: ON with no load.
Cable length: 1 m.
Model: NPN output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bottoms of the cassettes
LY3N-J AC200/220
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator.
Optical detection of actuator operation provides a long life,
(mechanical life: 5 million operations min LY3N-J AC200/220. ).
Models available with PNP or NPN output.
Models are available with very flexible robot cable. Fitting materials: Iron, black coating.
Count: 1 .
Accessories: Description, None;
Material, --;
Count, --.
Applicable sensor (mounting pitch on sensor side): E3Z-G.
Page: Dimensions, 14. Isolation: Photocoupler.
Zero cross function: Yes LY3N-J AC200/220.
Indicator: Yes(Yellow).
Applicable output load (See note 1 . ): 40 A at 200 to 480 VAC.
Rated input voltage: 5 to 24 VDC.
Wide Lineup of General-purpose Solid State.
Relays with Applicable Loads of 5 to 90 A.
AC Output Relays with 75-A and 90-A output currents have been,
added to the G3NA Series.
All models feature the same compact dimensions to provide a,
uniform mounting pitch.
Built-in varistor effectively absorbs external surges.
(except G3NA-D210B).
Operation indicator enables monitoring operation.
Protective cover for greater safety.
Standard models certified by UL and CSA and -UTU models by TÜV.
(except G3NA-410B, G3NA-420B, and G3NA-440B(-2)). Time specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time vallue can be checked eeasily because operation time,
is indicated from the start of operation LY3N-J AC200/220.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequeenccy, basic,
frequency, and load conditions LY3N-J AC200/220. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
LY3N-J AC200/220 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=LY3N-J AC200/220&select=5