Rated voltage: 100 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2700 r/min; 60 Hz, 3100 r/min.
Maximum flow rate: 50 Hz, 2.6 m3/min; 60 Hz, 3.0 m3/min.
Maximum static pressure: 50 Hz, 86 Pa; 60 Hz, 48 Pa.
Noise: 50 Hz, 55 dB; 60 Hz, 56 dB .
Weight: Approx. 2220 g MK2KP DC100.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting
MK2KP DC100
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws) MK2KP DC100.
Optional Replacement Filter and Vent Attachment .
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Contact type: Microload (125 VAC, 0.1 A; 30 VDC 0.1 A).
Operation: Momentary operation (Self-resetting).
Output: DPDT.
Lighting: LED, 12 VDC.
Operation Unit color symbol: Enter the desired color symbol for the Pushbutton,
in @ MK2KP DC100. R (Red); Y (Yellow); G (Green); A (Blue); W (White).
Pushbutton Switch Series with.
Square 40-mm Body.
Combines miniature design with distinct but soft sense of operation.
Easy panel mounting from the front and simple lamp replacement.
without tools. Classification: Models with built-in diodes.
Rated voltage: Standard products, 12, 24, or 100/110 VDC;
Made-to-order items, 48 VDC.
New Latching Levers for Circuit Checking.
Added to Our Best-selling.
MY General-purpose Relays.
Now lead-free to protect the environment.
VDE certification (Germany).
Different colors of coil tape for AC and,
DC models to more easily distinguish them.
MY(S) models with latching levers added for,
easier circuit checking. Name: Bit Slave Units with e-CON Connectors.
Specifications: Outputs; 2 outputs; PNP.
Simple and Intelligent Bit Slaves,
with Industry-standard e-CON connectors.
Slave Units capable of 2-point bit-level distribbution MK2KP DC100.
The I/O power suupply is supplied from the communications,
power in the previously connected flat cable, and has a,
short-circuit detection function for protection .
Industry-standard e-CON connectors.
Short-circuit protection safeguards the network,
from I/O shhort circuits MK2KP DC100.
Simple communications connections,
with flat cable and connectors.
Bit-level distribution to support,
essentially any application.
MK2KP DC100 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MK2KP DC100&select=5