Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function .
Event entry point: 4.
Transfer output: transfer output (special terminal) MK2P2-I DC6.
Remote SP:4 to 20mA input
MK2P2-I DC6
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 MK2P2-I DC6. 01 degrees C .
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver MK2P2-I DC6. 4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output .
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. An Ideal Indicator for OK/NG Judgements in Automated and,
Picking Machines, Measuring Factors such as Pressure,
Load, Torque, and Weight Using Load Cell Signal Input.
Easy recognition of judgement results using color display that can be switched,
between red and green.
Equipped with a position meter for monitoring operating status trends.
External event input allows use in various measurement and discrimination, applications.
Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported).
External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC,
power takeoff also available.).
Series expanded to include DeviceNet models.
Short body wiith depth of only 95 mm ((from behind the front panel), or 97 mm,
for DeviceNet models MK2P2-I DC6.
UL certification approval (Certification Mark License).
CE Marking conformance by third party assessment body.
Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66).
CCappable of high-speed sampling at 50 times per second (20 ms) MK2P2-I DC6.
• Easy-to-set two-point scaling allows conversion and display of any,
user-set values.
MK2P2-I DC6 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MK2P2-I DC6&select=5