Size: M12 (Brass); Single; Unshielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Size: M12 (Brass); Single; Unshielded.
Sensing distance: 10 mm.
Connecting method (See note 1 . ): M12 Connector.
Body length: Long MKS3PI-5 DC12.
Output configuration: PNP.
Operation mode NC
MKS3PI-5 DC12
A new generation in global applications. Connects Power Supply Adapter and SYSMAC NET Link Unit.
For 2 Unit.Cable specifications: Fire-retardant, Robot cable.
Cable length L: 0.3 m.
Cable outer diameter: 6 mm.
Angled Connectors.
Minimum order: 10.
UL: Yes MKS3PI-5 DC12.
Round Water-resistive Smartclick .
Connectors That Reduce Installation Work.
A newly developed lock mechanism that is compatible with round M12 connectors.
Simply insert the Connectors, then turn them approximately 1/8 of a turn to lock.
A positive click indicates locking.
Features the same degree of protection (IP67) as M12 connectors.
A full line-up of models is planned.
Connectors with Cables are UL approved MKS3PI-5 DC12. Name: Basic Unit (temperature control) *1 .
Power supply voltage: 24 VDC supplied from the End Unit.
No. of control points: 2.
Control outputs 1 and 2: Current output: 2 points.
Control outputs 3 and 4: Transistor output: 2 points (sinking).
Auxiliary output: None.
Functions: burnout Heater alarm, None; Event inputs, 2.
Communications functions: G3ZA connection port: RS-485,
From End Unit: Port A or port B: RS-485.
Input type: Thermocouple, platinum resistance thermometer,
analog voltage, and analog current selectable for each channel.
Terminal: M3 terminal.
In-panel Temperature Controller with Flexible,
Modular Design and Wide Integration with Host,
Devices.
The compact modular structure enables construction of temperature,
systems optimally suited to the application.
Connection can be made to a Programmable Controller without any,
programming required, reducing the number of steps required in ladder,
programming design.
One fully universal-input Unit includes a thermocouple, platinum-resistance,
thermometer, and analog input for easy selection and reduced inventory,,
requirements MKS3PI-5 DC12.
Conneect directly to the G3ZA Multi-channel Power Controller using,
optimum cycle control for high-accuracy regulation with minimal noise .
Autotuning (AT) can be used for independent heating/cooling PID control.
Self-tuning (ST) can be used to calcullatte the PID constants with the step,
response method MKS3PI-5 DC12.
Up to 16 Temperature Controllers can be connected to a single DeviceNet,
Communications Unit.
MKS3PI-5 DC12 Operation manual / Instructions / Catalog download link:
/searchDownload.html?Search=MKS3PI-5 DC12&select=5